Download MBB Network & Wireless Cards Driver

Mobile Broadband is a Data SIM granting you internet access at speeds faster than ever with our 4G+data bundles!
Insert the SIM in a compatible device of your choice ( router, dongle, tablet or mobile phone), subscribe to Mobile Broadband bundle and connect to the internet on the go.

Download mbb network access

After back-to-back road games, Arkansas returns to Bud Walton Arena to host Auburn on Wednesday (Jan. Tipoff is set for 8 pm and the game will be televised on SEC Network. MBB Network Adapter Class Extension is unable to start, if the Network Adapter Wdf Class Extension Library service is stopped or disabled. Restore Default Startup Type for MBB Network Adapter Class Extension Automated Restore. Select your Windows 10 edition and release, and then click on the Download button below.

Mobile Broadband bundles for Prepaid and Postpaid


1 month validity bundles

Bundles

Prices*

Extra MB

SMS to 1050

500 MB

$10

$0.10

MBB500

1.5 GB

$17

$0.08

MBB1.5

5 GB

$23

$0.07

MBB5

10 GB

$30

$0.07

MBB10

20 GB

$39

$0.06

MBB20

30 GB

$47

$0.05

MBB30

40 GB

$59

$0.05

MBB40

60 GB

$69

$0.05

MBB60

70 GB

$79

$0.05

MBB70

100 GB

$107

$0.04

MBB100

200 GB

$194

$0.04

MBB200

*All prices above are VAT Excluded for Postpaid MBB

3 months validity bundles

Bundles

Price*

Extra

SMS to 1050

70 GB

$ 139

$0.05/MB

3MBB70

100 GB

$ 179

$0.04/MB

3MBB100

200 GB

$ 259

$0.04/MB

3MBB200

*All prices above are VAT Excluded for Postpaid MBB


How Much It Costs

Prepaid

Driver

Line Price:$18.87 (VAT INCLUDED)
Available Credits: $17
Validity: 30 DAYS (30 DAYS initiation period to activate a bundle)
Retention: 0

Postpaid

Sim Card fees: $5 (VAT Excluded)
No deposit is required when purchasing up to 2 lines
$100 as of the 3rd line
$250 when exceeding 5 lines (including voice lines)

How To Subscribe/Unsubscribe

  • Press *111# and follow the steps (The card must be inserted in a handset)
  • Send an SMS for free to 1050 by referring to the above tables
  • Online (Available only for the 1 month validity bundles)
  • Alfa Mobile Application (Available only for the 1 month validity bundles)


How to modify*

  • Dial *111# and follow the steps (The card must be inserted in a handset)
  • Send an SMS for free to 1050 enclosing MMBB for the 1 month data bundles, M2MBB for the 2 months data bundles and M3MBB for the 3 months data bundles.
  • Online (Available for the 1 month validity bundles)
  • Alfa Mobile App(Available for the 1 month validity bundles)

* Modification for Prepaid subscribers will remain pending and effective on the renewal date of the active bundle. As for Postpaid subscribers, modification will be applicable immediately and charges for the new bundle will apply.

Download mbb network login

How to renew
- Instant renewal
Instant renewal is only allowed when MBs are totally consumed within the same lifecycle.

  • Dial *111# and follow the steps (The card must be inserted in a handset)
  • Send an SMS for free to 1050 enclosing RMBB for the 1 month data bundles, R2MBB for the 2 months data bundles and R3MBB for the 3 months data bundles.
  • Online (Available for the 1 month validity bundles)
  • Alfa Mobile App (Available for the 1 month validity bundles)

Download MBB Network & Wireless Cards Drivers

Analyzer

- Auto Data Renewal(Available for the 1 month validity bundles)
Once you send AR to 1050 the following Data bundles, Mobile Internet, Mobile Broadband, Alfa5x5 will be automatically renewed every time your MBs are fully consumed.
- To Activate:
• Online
• Send AR to 1050 free of charge
• Dial *111# and follow the steps
- To Deactivate
• Online
• Dial *111# and follow the steps

Download Mbb Network & Wireless Cards Drivers

Click here for more info on the Auto Data Renewal feature for Prepaid

To recharge, you can select any of the following Alfa recharge cards (VAT Excluded): $3.64, $9.09, $15.15, $17.06, $22.73, $27.27, $45.45, $68.18, and $136.36 ($17.06 and $136.36 available at the ATM machines of affiliated banks). The recharge cards will only allow you to top up your account with credit.

How To Check Your Consumption

  • Dial *111# and follow the steps (The card must be inserted in a handset)
  • Online (Available for the 1 month validity bundles)
  • Alfa Mobile Application(Available for the 1 month validity bundles)

Business

How Much It Costs

Sim Card fees: $5 (VAT Excluded).
Monthly subscription depending on the data bundle activated according to the corporation plan.

Mobile Broadband for Business

Data Bundle

Prices Per Corporation

Small - Medium
5-20 / 21-50
Large
51+

500 MB

$8.50
$0.085/MB
$8
$0.080/MB

1.5 GB

$14.45
$0.068/MB
$13.60
$0.064/MB

5 GB

$19.55
$0.06/MB
$18.40
$0.056/MB

10 GB

$25.50
$0.06/MB
$24
$0.056/MB

20 GB

$33.15
$0.051/MB
$31.20
$0.048/MB

30 GB

$39.95
$0.042/MB
$37.60
$0.042/MB

40 GB

$50.15
$0.042/MB
$47.20
$0.042/MB


60 GB

$58.65
$0.042/MB
$55.20
$0.042/MB
70 GB$67.15
$0.042/MB
$63.20
$0.042/MB

100 GB

$90.95
$0.040/MB

200 GB

$164.90
$0.040/MB

*All prices above are VAT Excluded


How to Subscribe/Unsubscribe
Only administrators can subscribe/unsubscribe/modify/renew the service:

  • Call 111 from the administrator number
  • Send email: alfa.customercareteam@alfamobile.com.lb from the authorized e-mail address

How To Check Your Consumption

  • Accessible only for prepaid lines: dial *111# and follow the steps (the card must be inserted in a handset)
  • Dial *11# (the card must be inserted in a handset)
-->

A mobile broadband (MBB) device provides a mobile computer with a wireless data connection to a cellular service. An MBB device supports one or more cellular radio technologies, such as GSM, 3G, CDMA, or LTE. MBB devices in modern standby platforms are all required to provide the same set of power management capabilities and to implement the same general hardware configuration, regardless of the specific cellular technologies supported.

The MBB device is expected to use Universal Serial Bus (USB) to connect to the modern standby platform, and to use software provided by Microsoft for all connectivity and power management operations. Windows includes an inbox Mobile Broadband Class Driver, which provides a standardized interface for mobile broadband data transfer, connection management, and power management for MBB radios. The following guidance focuses on power management for MBB devices that are integrated inside the mobile computer chassis. MBB devices that connect to an external USB port are not discussed.

During modern standby (when the screen is off), the MBB device is expected to be in a low-power state. How much power the MBB device consumes in this low-power state depends on whether the user has provisioned the MBB device on the cellular network. If the MBB device is provisioned and the radio in the device is currently enabled by the user for a data connection, the device should be in a low-power connected-sleep mode in which the device's USB function is in the D2 (suspend) device power state. However, if the MBB device has not been provisioned on the network or the user has disabled the radio for a data connection, the device should be in a low-power radio-off mode. In radio-off mode, the MBB device has only enough power applied to respond to host commands over the USB interface.

The implementation of MBB device power management for a modern standby platform is based on the following:

  • The user-controlled radio power state of the MBB device.
  • The USB bus suspend and resume transitions.

The MBB device must be able to enter a low-power D2 (suspend) state after the MBB radio is turned off and the USB bus interface enters the suspend state. All sleep and wake power transitions must be signaled over the USB bus. There is no support for out-of-band GPIO signaling to initiate MBB device power transitions or to interrupt the main processor on the System on a Chip (SoC) or core silicon.

If the radio in the MBB device is currently enabled by the user for a data connection, the device must be able to use in-band, USB resume signaling to wake the SoC or core silicon from modern standby. The SoC or core silicon must be able to wake from its lowest power state in response to in-band, USB resume signaling from the MBB device.

Power management modes

The MBB device is expected to support five power-management modes.These modes are a combination of provisioned, connectivity, and radio power states. A transition from one mode to another is communicated to the device directly over the USB bus through commands from the Mobile Broadband Class Driver or USB device state transitions. Transitions between power management modes must not use external GPIO signaling.

The five power-management modes are:

Active

The radio is actively transmitting data or is actively connected to the cellular network.

Connected-sleep

The radio is provisioned on the network and a user account is enabled. The platform is in modern standby. The MBB device is waiting for data from the network to wake up the SoC, and also for events from the SoC. Average across 2G, 3G, LTE, and various DRX modes.

Radio-off

The radio is provisioned on the network, but Windows or the user has turned off the radio in the MBB device.

No-subscription

The user does not have an active subscription.

No-SIM

The device has no SIM.

The following table compares the five power-management modes.

Power management modeRadio power stateUSB device power state (Dx)Average power consumptionExit latency to active

Active

On

D0

Scenario-specific

N/A

Connected-sleep

On

D2 (selective suspend)

<= 15 milliwatts (device-specific)

USB D2 -> D0 <= 400 milliseconds (USB specification)

Radio-off

Off

D2 (selective suspend)

<= 5 milliwatts

USB D2 -> D0 < 400 milliseconds + Base station acquisition and registration (specific to location and carrier)

No-subscription

Off

D2 or D3

<= 3 milliwatts

N/A

No-SIM

Off

D2 or D3

<= 3 milliwatts

N/A

Note In no-subscription mode and no-SIM mode, an MBB device can be in either the D2 or D3 device power state, depending on whether the device supports D3.

The power consumption of the MBB device in each of the power modes shown in the preceding table will vary by radio implementation, network type, and distance from the cellular access point. Contact the radio manufacturer for information about the device-specific power consumption in each power management mode shown in the preceding table.

Software power management mechanisms

The two primary software power management mechanisms for the MBB device are the radio power state and the USB function power state.

Radio power state

The Windows Mobile Broadband Class driver will send a MBIM_CID_RADIO_STATE message to the MBB device with a command to turn the radio power state to on or off per the user's preference. When the user disables the radio, the Mobile Broadband Class driver will send the MBIM_CID_RADIO_STATE message with an MBIMRadioOff command.

USB selective suspend

The Windows Mobile Broadband Class Driver is a Windows Network Driver Interface Specification (NDIS) miniport driver. The Mobile Broadband Class Driver and NDIS collaborate to manage the power of the MBB device. Windows will transition the USB function of the MBB device to the USB suspend (or, in Windows terminology, selective suspend) state when the MBB device should be in a low-power mode. The transition to the USB suspend state is independent of the radio power state.

Windows will transition the MBB device to connected-sleep mode (USB suspend (D2) state) when the system enters modern standby and the device is provisioned on the network. During connected-sleep mode, the radio is on, and the MBB device is expected to generate USB resume wake signaling and return to the D0 state when the radio receives new data from the network that matches programmed wake patterns or when other enabled wake events occur. The power consumption in connected-sleep mode will vary by cellular technology and distance from the cellular access point.

Windows will transition the radio to radio-off mode (USB suspend (D2) state) when the system enters modern standby and the device is provisioned on the network, but the user has set the radio power state to off. In radio-off mode, the MBB device is expected to consume no more than five milliwatts on average. The following block diagram shows the control path for initiating the MBB device's transition to the USB suspend state.

If the MBB device has not been provisioned on the network by the user, Windows will transition the device to the no-subscription mode (D2 or D3 state) when the platform enters modern standby. When the device is in no-subscription mode, its radio power state is always off. When the MBB device is in the no-subscription mode during modern standby, the power consumption of the MBB device is expected to be equivalent to that of the radio-off mode. However, the MBB device must still remain physically enabled on the USB bus during the entire time that the device is in the no-subscription mode.

At all times—regardless of whether the platform is in modern standby—power must not be removed from the USB function portion of the MBB device. Otherwise, when power is removed, the device will fall off of the USB bus and cause the device to be reported as surprise-removed.

Note On modern standby platforms, there is no support for the execution of third-party driver or ACPI firmware to manage transitions of the MBB device between the power management modes previously described. All power management of the device must be done in-band through the USB bus.

Third-party driver and ACPI firmware is supported for Specific Absorption Rate (SAR) sensors, which change the MBB radio transmitter power in reaction to the proximity of the MBB antenna to the user.

Supported hardware power configurations

To meet the power management requirements of a modern standby platform, only one hardware configuration is supported—the MBB device must use USB to connect to the platform. Additionally, the USB-connected MBB device must:

  • Report that it is self-powered and remote-wake-capable in the USB configuration descriptor for the device.
  • Be attached to a system power rail that will be powered on at all times regardless of whether the platform is in modern standby.

Because there is no support for the execution of third-party driver or ACPI firmware for MBB device power management, there must be no GPIO lines connected from the MBB device to the SoC for use by the operating system or third-party driver software. All power management of the MBB device must be communicated in-band over the USB bus.

MBB module reset

The MBB device must undergo a reset when the platform enters the ACPI S5 (shutdown) system power state. This requirement exists so that the user can indirectly reset the MBB device if it is not responsive by selecting Restart from the Windows Power menu. In addition, this requirement ensures that the MBB device can be reset to detect a newly inserted or removed SIM.

The system integrator should ensure that the system resets the MBB device using one of the following methods:

  • Reset in UEFI firmware: The system UEFI firmware can reset the MBB device on system boot. Note that Windows requires platforms that have non-rotational (solid-state) storage to complete power-on self test (POST) within two seconds. Resetting the MBB device must not cause this time to be exceeded.
  • Remove power with switchable power rail: The system integrator can design the platform power routing to remove power from the MBB device when the platform enters the S5 state. The removal of power from the device be accomplished by using a GPIO-controlled power switch or by placing the MBB device on a power rail that is disabled by the system power-management IC (PMIC) when the platform enters the S5 state.

Wake concerns

An MBB device that is in the USB suspend state must be able to wake the SoC by using USB resume signaling. The SoC must be able to wake from its lowest run-time idle state on detection of a USB specification-compliant resume-from-suspend signal from an attached USB device.

A USB-connected MBB device that is located inside the computer chassis will typically be self-powered. That is, the device draws its power from a system power rail instead of from the USB host controller to which it is attached. The reason for this requirement is that some MBB devices (depending on the cellular technology) require more than the USB specification-allotted suspend current to stay connected to the network during connected-sleep mode.

Testing and validation

The MBB device vendor, the system integrator, and the SoC designer should test the MBB device's USB power management and verify that it is functioning correctly. Specifically, the MBB device should transition to the D2 (USB suspend) device power state and stay in this state during modern standby when the device is not actively transmitting or receiving data. In addition, verify that the MBB device can use in-band USB resume signaling to wake the SoC from its deepest idle state when data is transmitted to the MBB device over the cellular network.

Power management checklist

System integrators, MBB device vendors, and SoC designers should review the checklist below to ensure that their system power management design is compatible with Windows 8 and Windows 8.1.

  • Select a MBB device that implements support for the Windows Mobile Broadband Class Driver and the Mobile Broadband Interface Model (MBIM).

  • Windows includes all of the built-in software required to enumerate, describe, communicate with, and power-manage the MBB device. No additional software is required or supported.

    Verify that your MBB device does not require additional driver software or firmware support on the SoC for power management.

  • The MBB device hardware must:

    • Report the self-powered and remote-wake capabilities in the USB descriptor for the device.
    • Be capable of using in-band USB resume signaling to wake the SoC when data from the cellular network is ready for processing.
    • Not require any GPIO lines between the MBB device and the SoC to generate wake signaling or enter low-power modes.
    • Not generate spurious USB in-band wakes. The MBB device must wake the SoC only when data matching programmed patterns arrives for the SoC or other enabled wake events occur.
  • The MBB device must be reset when the platform enters the S5 (shutdown) system power state. The system integrator must either:

    • Reset the MBB module in system UEFI boot firmware during POST. Note that Windows requires a modern standby platform to complete POST within two seconds.
    • Place the MBB module on a power rail that is turned off when the platform is in the S5 state. The rail can be turned off by a GPIO-controlled switch or by the system PMIC.
  • The SoC used in the platform design must be capable of detecting a USB resume signal and waking from its lowest power state.

  • System integrators should verify that the power consumption of the MBB device in the radio-off and no-subscription modes meets the previously described requirements.